揚州國(guo)華(hua)電(dian)氣專業銷售-回路電(dian)阻(zu)測(ce)試儀(yi),電(dian)阻(zu)測(ce)試儀(yi)是采(cai)用數字(zi)電(dian)路技(ji)術和開(kai)(kai)(kai)關電(dian)路技(ji)術制(zhi)作,它是用于(yu)開(kai)(kai)(kai)關控(kong)制(zhi)設備的接觸電(dian)阻(zu),回路電(dian)阻(zu)測(ce)量的設備,用數字(zi)顯(xian)示,該(gai)儀(yi)器測(ce)量準確、性(xing)能穩(wen)定(ding)、適合電(dian)力,供(gong)電(dian)部門現場(chang)高壓開(kai)(kai)(kai)關維(wei)修和高壓開(kai)(kai)(kai)關廠回路電(dian)阻(zu)測(ce)試的要求。
回(hui)路電阻測試儀主要(yao)功(gong)能
按照GB10963-1999家用及類似場(chang)所(suo)用過電流保護斷路(lu)器標準規定(ding)斷路(lu)器應(ying)做脫扣特(te)性試驗。
1)時間-電(dian)流(liu)特性試驗
①從冷態開(kai)始,對(dui)斷路器(qi)通以1.13In(約定(ding)不脫(tuo)扣(kou)電(dian)(dian)流(liu)(liu))的電(dian)(dian)流(liu)(liu)至約定(ding)時間,斷路器(qi)不應脫(tuo)扣(kou)。然后在5s內把電(dian)(dian)流(liu)(liu)穩定(ding)升至1.45In(約定(ding)脫(tuo)扣(kou)電(dian)(dian)流(liu)(liu))的電(dian)(dian)流(liu)(liu),斷路器(qi)應在約定(ding)時間內脫(tuo)扣(kou)。
②從冷(leng)態開始,對斷(duan)(duan)路器的各級通(tong)以2.55In的電流,斷(duan)(duan)開時(shi)間(jian)應(ying)大(da)于(yu)1s,并且(qie)對于(yu)額定電流小(xiao)于(yu)等于(yu)63A的斷(duan)(duan)路器斷(duan)(duan)開時(shi)間(jian)應(ying)小(xiao)于(yu)60s,對于(yu)額定電流大(da)于(yu)63A的斷(duan)(duan)路器斷(duan)(duan)開時(shi)間(jian)應(ying)小(xiao)于(yu)120s。
③對于D型斷路(lu)器(qi):從(cong)冷態開(kai)(kai)始,對斷路(lu)器(qi)的(de)各級通(tong)(tong)以10In的(de)電流(liu),斷開(kai)(kai)時間(jian)(jian)應大于0.1s;然后再從(cong)冷態開(kai)(kai)始,對斷路(lu)器(qi)的(de)各級通(tong)(tong)以50In的(de)電流(liu),斷開(kai)(kai)時間(jian)(jian)應小于0.1s。這兩個試驗均應滿足時間(jian)(jian)-電流(liu)動作特性表。
揚州國華電氣專業銷售-回路電阻測試儀是采用(yong)數(shu)(shu)字電(dian)(dian)(dian)路技(ji)術(shu)和開(kai)(kai)關(guan)電(dian)(dian)(dian)路技(ji)術(shu)制(zhi)作,它是用(yong)于開(kai)(kai)關(guan)控制(zhi)設備(bei)的(de)接(jie)(jie)觸電(dian)(dian)(dian)阻,回路電(dian)(dian)(dian)阻測(ce)量的(de)設備(bei),其測(ce)試電(dian)(dian)(dian)流采用(yong)國(guo)家標準GB763推(tui)薦的(de)100A直流,可在100A電(dian)(dian)(dian)流的(de)情況下直接(jie)(jie)測(ce)得回路電(dian)(dian)(dian)阻或接(jie)(jie)觸電(dian)(dian)(dian)阻,并用(yong)數(shu)(shu)字顯示(shi),該(gai)儀器(qi)測(ce)量準確、性能穩定、適合(he)電(dian)(dian)(dian)力,供電(dian)(dian)(dian)部門(men)現場高壓開(kai)(kai)關(guan)維修和高壓開(kai)(kai)關(guan)廠(chang)回路電(dian)(dian)(dian)阻測(ce)試的(de)要求(qiu)。
技術性能
· 測(ce)量范圍(wei):0-1999μΩ 分辨率:1μΩ
· 測量電流:>100ADC
· 測量精度:0.5級±2個字
· 顯示(shi)(shi)方式(shi):液晶顯示(shi)(shi)、結果(guo)打印
· 工作(zuo)溫度:-10℃~50℃
· 工作電流:AC220V±10%
· 體 積:290×280×240
· 重 量:6.2Kg